Home : LinkTools version error
LinkTools version error

LinkTools version error

 

When running an interface with HI-IQ and LinkTools, and LINK TCP/IP Receiver displays a message that contains “Invalid Version[2.3.1]” in the MSH segment,  HL7 version is configured incorrectly.

In this example, the correct ‘HL7 Version’ should be 2.3.1.

To correct the HL7 version number,

1)      locate the LINKTools® TCP/IP Receiver shortcut icon from the computer desktop on the server on which the HI-IQ interface is installed,

2)      double-click to open,

3)      click on Options icon. 

4)      Edit the version number in ‘HL7 Version’ field to equal the version in parenthesis in the “Invalid Version” LinkTools message.

5)      Press ‘OK’.

6)      Press ‘OK’ to save the change.

7)      Restart LinkTools.

NOTE: The following illustration of LinkTools is from the website: www.linkmed.us.

In this example, the field number 7, ‘HL7 Version’ would be changed from 2.3 to 2.3.1, and saved.

Then LinkTools would be restarted.

 

Updated - kl 4/2/2010

Related Articles
No Related Articles Available.

Article Attachments
No Attachments Available.

Related External Links
No Related Links Available.
Help us improve this article...
What did you think of this article?

poor 
1
2
3
4
5
6
7
8
9
10

 excellent
Tell us why you rated the content this way. (optional)
 
Approved Comments...
No user comments available for this article.
Created on 8/13/2007.
Last Modified on 4/2/2010.
Last Modified by Kevin Lauzon.
Article has been viewed 388 times.
Rated 0 out of 10 based on 0 votes.
Print Article
Email Article


ConexSys
HI-IQ Knowledge Base. Copyright © 2004


Society of Interventional Radiology